Question 1

How do you document a VI so that the description appears in the Show Context Help popup window?


  • A: Use the VI Properties Documentation window
  • B: Type in the Show Context Help window
  • C: Create a free label on the front panel
  • D: Edit the LabVIEW help files
Question 2

Can a wire be used to pass data between loops that are intended to run in parallel?


  • A: Yes
  • B: No
Question 3

Which of the following describes a Tab Control?


  • A: A control that outputs ASCII values equal to the selected tab label
  • B: A type of enumerated control
  • C: A control that outputs a cluster of the controls / indicators on the tabs
  • D: A controls that outputs the tab order of the controls on the front panel
Question 4

What is an advantage of using a Strictly Typed VI ref num?


  • A: The data types of the target VI are known at compile time
  • B: The data types passed to the VI can change programmatically
  • C: You can flatten the data to a string to improve code performance
  • D: Causes dynamically loaded VIs to be loaded at the start of execution
Question 5

A coercion dot indicates that:


  • A: The data types are consistent
  • B: A polymorphic operation will be performed on the data
  • C: A data buffer is created to handle data conversion
  • D: Data values are being coerced because they are out of range
Question 6

Which of the following statements is true about the following block diagram? 
 
  


  • A:
      
    The loop will execute once and the iteration terminal, , will output a value of one
  • B:
      
    The loop w ill execute once and the iteration terminal,, will output a value of zero
  • C: The loop will execute infinitely and the program will have to be aborted
  • D:
      
    The loop will not execute and the iteration terminal, , will return a null value
Question 7

Which of the following can not be used to transfer data?


  • A: Semaphores
  • B: Queues
  • C: Notifiers
  • D: Local variables
Question 8

Which of the following terminals controls how many times a For loop executes? 
 
  


  • A: Option A
  • B: Option B
  • C: Option C
  • D: Option D
Question 9

You have a control on the front panel of a VI and you need to modify one of its properties at run time. Which of the following is the best approach you would take?


  • A: Create an implicit property node and select the property to modify
  • B: Create a control reference, pass the reference to a property node and select the property to modify
  • C: Create a linked shared variable and select the property to modify the property
  • D: Create a local variable and select the property to modify
Question 10

Formula nodes accept which of the following operations?


  • A: Basic programming language instructions Input and Print
  • B: Embedding of SubVIs within the Formula Node
  • C: Pre and post increment (++) and decrement (--) as in the C language
  • D: The use of nested Formula Node structures



Comments