Download NetApp Certified Implementation Engineer - SAN Specialist.NS0-509.Pass4Sure.2020-04-14.30q.vcex

Vendor: Network Appliance
Exam Code: NS0-509
Exam Name: NetApp Certified Implementation Engineer - SAN Specialist
Date: Apr 14, 2020
File Size: 2 MB

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Demo Questions

Question 1
You are testing iSCSI LUN failover across a 4-node FAS9000 fabric-attached MetroCluster configuration. 
In this scenario, which front end configuration is required for nondisruptive host LUN failover between sites?
  1. an intercluster LIF
  2. a stretched Layer 2 network
  3. IPv6
  4. a stretched VSAN
Correct answer: A
Question 2
Click the Exhibit button. 
  
Referring to the exhibit, which two pairs of ports are currently configurable as FC SAN LIFs? (Choose two.)
  1. 01b, 0h
  2. 01a, 0g
  3. 01a, 0h
  4. 01b, 0g
Correct answer: D
Question 3
You have a thin-provisioned LUN that was created by using the lun create -vserver vs1 -path /vol/vol1/lun1 -size 500G -ostype windows_2008 -space-reserve disabled -space-allocation disabled command. 
You verify that your Windows 2016 host reports 200 GB free on lun1. However, lun1 shows 0 bytes free on the storage cluster. 
What should you do to solve this problem?
  1. Change the LUN -space-allocation parameter to enabled.
  2. Change the LUN -ostype parameter to windows_gpt. 
  3. Change the LUN -space-reserve parameter to enabled.
  4. Rescan the LUN disk in your Windows host so that it will notify NetApp about the free space.
Correct answer: D
Question 4
Click the Exhibit button. 
  
Referring to the exhibit, what happens when you change the type for port 1a from target to initiator?
  1. The port type for 1a changes to initiator, and you must reboot the controller for the changes to take effect.
  2. You receive an error message that you must take ports 1a and 1b offline before you can change the type.
  3. B. You receive an error message that you must take the port 1a offline before you can change the type.
  4. The port type for 1a and 1b changes to initiator, and you must reboot the controller for the changes to take effect.
Correct answer: A
Explanation:
Question 5
A customer has an existing 8-node cluster that consists of six FAS2650 nodes and two FAS2554 nodes. The customer wants to expand the cluster by adding two AFF A220 nodes. 
Which resource would be used to determine whether this configuration is supported?
  1. Interoperability Matrix Tool (IMT)
  2. Config Advisor
  3. OneCollect
  4. Hardware Universe (HWU)
Correct answer: B
Question 6
You deployed a new SVM for FC access, and you used the vserver fcr, create -vserver svm1 - status-admin up command to enable FC service on the SVM. You then created the LIFs for the FC protocol. When you review the status of the LIFs, they show that the admin status is up, but the operational status is down. You have already verified that the ports are physically connected.  
In this scenario, what is the next step to bring the LIFs up?
  1. Use the network interface modify command to change the operational status of the LIFs.
  2. Create at least one zone that contains your SVM LIF WWPNs and an initiator.
  3. Verify that an FC license is applied on your system.
  4. Disable the SAN switch port where your NetApp storage is connected.
Correct answer: B
Question 7
Click the Exhibit button. 
  
A customer wants to add a 2-port, 32 Gb FC card to support NVMe in an AFF A700 2-node cluster. Currently, there are cards in slots 1, 2, 4, 6, 8, and 9.  
Referring to the exhibit, what is the number of the slot that should be used?
  1. 10
  2. 3
  3. 5
  4. 7
Correct answer: C
Question 8
You use iSCSI to present a LUN to a newly installed Windows 2016 Server. You have created the volume and LUN on the NetApp cluster. When you perform a hardware rescan on the Windows host, you cannot see the newly presented storage.  
What are three reasons for this problem? (Choose three.)
  1. The protocol has not been enabled on the NetApp cluster.
  2. You need to add the IQN of the Windows host to the newly created LUN.
  3. The IQN of the Windows host is not included in the igroup for the new LUN.
  4. The wrong igroup has been associated with the new LUN.
  5. The volume has not been enabled for iSCSI access.
Correct answer: ABD
Question 9
You want to create an additional SVM from the System Manager GUI to serve data only using block-based protocols. You know the SVM name, the aggregate containing the root volume, and the required protocols.  
What other information is required to successfully create this SVM?
  1. name servers
  2. SVM Management LIF network details
  3. search domains
  4. root volume security style
Correct answer: D
Question 10
An administrator is configuring their Ethernet switches to support an AFF A300 cluster that will be providing iSCSI LUNs to servers. The switches are also used for other traffic from various hosts.  
In this scenario, which statement about the switch configuration is correct?  
  1. Use a larger MTU size at the SAN connection rather than the host connections to allow for greater SAN bandwidth.
  2. Use network ports as access ports only.
  3. Use multiple VLANs to segregate iSCSI traffic from other traffic types
  4. Use a single VLAN to consolidate all data traffic on the switches.
Correct answer: A
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!