Download NetApp Certified Implementation Engineer - SAN Specialist.NS0-509.Pass4Sure.2019-09-30.35q.vcex

Vendor: Network Appliance
Exam Code: NS0-509
Exam Name: NetApp Certified Implementation Engineer - SAN Specialist
Date: Sep 30, 2019
File Size: 3 MB

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Demo Questions

Question 1
  
You are asked to serve iSCSI LUNs in an existing SVM on your AFF A220 using ONTAP 9.5. You verified that the iSCSI license is configured on your cluster and that the iSCSI protocol is enabled.  
Referring to the exhibit, what is needed to allow hosts to log into the iSCSI target?
  1. Create new LIFs with the iSCSI data protocol.
  2. Create new igroups with the host IQNs.
  3. Add iSCSI to the data protocol of the existing LIFs.
  4. Map LUNs to the igroups.
Correct answer: D
Question 2
You have a 4-node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 volumes that use under 5000 IOPS are moved to a FAS8200 using the volume move command. 
In this scenario, what happens to the data after the volume is moved? (Choose two.)
  1. The new written data is not compacted.
  2. The existing data is compacted.
  3. The new written data is compacted.
  4. The existing data is not compacted.
Correct answer: A
Explanation:
Reference: https://www.netapp.com/us/media/tr-4476.pdf
Reference: https://www.netapp.com/us/media/tr-4476.pdf
Question 3
You are provisioning storage to an ESX host that uses iSCSI.  
According to NetApp best practice, which three actions accomplish this task? (Choose three.)
  1. Enable the iSCSI service.
  2. Bind the iSCSI ports to the software iSCSI adapter.
  3. Install Virtual Storage Console (VSC) for VMware.
  4. Enable BGP on the switch.
  5. Configure MTU 1500 on the switch.
Correct answer: BCE
Question 4
  
A customer has an AFF A700 connected to a Cisco switch and has verified connectivity but cannot see any LUNs. The customer issued the run -node scaling-01 -command fcp topology show command to verify the connection.  
Referring to the exhibit, what needs to be enabled on the Cisco switch?
  1. Trunking needs to be enabled.
  2. VSAN needs to be enabled.
  3. NPIV needs to be enabled.
  4. VFC needs to be enabled.
Correct answer: D
Question 5
  
A customer is using both FC and NVMe in a cluster. The customer needs to do some work on AFF_1. 
Referring to the exhibit, what will happen?
  1. The NVMe namespaces on AFF_2 will be available after takeover of AFF_1.
  2. The FC LUNs that use cluster interconnect to access the LUNs on AFF_1 will be unavailable after failover.
  3. The FC LUNs on node AFF_2 will be unavailable after failover of AFF_1.
  4. The NVMe namespaces on AFF_1 will be unavailable after takeover by AFF_2.
Correct answer: C
Question 6
  
You have an existing 2-node AFF A300 cluster with premium bundle licensing applied. You need to have consistently low front end latency, and have determined that NVMe satisfies this requirement.  
Referring to the exhibit, which two actions would accomplish this task? (Choose two.)
  1. Add a UTA2 adapter to each of the two AFF A300 nodes.
  2. Add a 32 GB FC HBA to each of the two AFF A300 nodes.
  3. Apply the license for FCP.
  4. Apply the license for NVMe.
Correct answer: B
Question 7
  
Referring to the exhibit, what happens when you change the type for port 1a from target to initiator?
  1. The port type for 1a changes to initiator, and you must reboot the controller for the changes to take effect.
  2. You receive an error message that you must take ports 1a and 1b offline before you can change the type.
  3. B. You receive an error message that you must take the port 1a offline before you can change the type.
  4. The port type for 1a and 1b changes to initiator, and you must reboot the controller for the changes to take effect.
Correct answer: A
Question 8
A customer that is using an AFF A220 has a problem with a host for a new FC LUN. Other LUNs on the same SVM are working properly. This LUN is not visible on the host.  
Which configuration does the customer need to verify in their solution?
  1. LUN mapping with igroup
  2. host HBA speed settings
  3. FC target port setting on NetApp node
  4. FC switch zoning
Correct answer: C
Question 9
You deployed a new SVM for FC access, and you used the vserver fcr, create -vserver svm1 - status-admin up command to enable FC service on the SVM. You then created the LIFs for the FC protocol. When you review the status of the LIFs, they show that the admin status is up, but the operational status is down. You have already verified that the ports are physically connected.  
In this scenario, what is the next step to bring the LIFs up?
  1. Use the network interface modify command to change the operational status of the LIFs.
  2. Create at least one zone that contains your SVM LIF WWPNs and an initiator.
  3. Verify that an FC license is applied on your system.
  4. Disable the SAN switch port where your NetApp storage is connected.
Correct answer: B
Question 10
  
A customer wants to add a 2-port, 32 Gb FC card to support NVMe in an AFF A700 2-node cluster. Currently, there are cards in slots 1, 2, 4, 6, 8, and 9.  
Referring to the exhibit, what is the number of the slot that should be used?
  1. 10
  2. 3
  3. 5
  4. 7
Correct answer: C
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!