Download FlexPod Implementation and Administration.NS0-171.PracticeTest.2017-12-18.57q.vcex

Vendor: Network Appliance
Exam Code: NS0-171
Exam Name: FlexPod Implementation and Administration
Date: Dec 18, 2017
File Size: 7 MB

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Demo Questions

Question 1
What are two valid cluster interconnect switches? (Choose two.)
  1. NetApp CN610
  2. Cisco Nexus 5596
  3. Cisco Nexus 9504
  4. Cisco Nexus 7004
Correct answer: AB
Explanation:
Reference https://library.netapp.com/ecm/ecm_get_file/ecmp1115327
Reference https://library.netapp.com/ecm/ecm_get_file/ecmp1115327
Question 2
A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC. When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown. 
What caused this issue?
  1. The Nexus switches do not have NPV enabled.
  2. The Nexus must be configured for FCoE instead of native Fibre Channel.
  3. The Nexus switches do not have NPIV enabled.
  4. The zoning on the Nexus switches is incorrect.
Correct answer: C
Explanation:
Reference https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-manager/whitepaper_c11-697337.html
Reference https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-manager/whitepaper_c11-697337.html
Question 3
Click the Exhibit button. 
   
An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect. 
Referring to the exhibit, how many ports will FC use after the configuration is completed?
  1. 16
  2. 2
  3. 1
  4. 6
Correct answer: A
Question 4
An administrator is configuring a Flexpod Datacenter solution. The UCS service profiles will use FCoE connectivity to the NetApp cluster. 
Which pool is needed to configure the vHBA templates?
  1. WWPN pool
  2. MAC pool
  3. IQN pool
  4. WWNN pool
Correct answer: A
Question 5
Which LIF role is used for SnapMirror traffic on a system running clustered Data ONTAP?
  1. intercluster
  2. node-management
  3. interconnect
  4. cluster-management
Correct answer: A
Question 6
Which set of commands maps VLAN 100 to VSAN 100?
  1. Nexus 5000-A#configure terminal 
    Nexus 5000-A (config) # vlan 100 
    Nexus 5000- A (config-vlan_ #fcoe vsan 100
  2. Nexus 5000-B# configure terminal 
    Nexus 5000-B (config) # vsan database 
    Nexus 5000-B (config-vsan)# vsan 100 
    Nexus 5000-B(config- vsan) #vsan 100 name FCoE-VLAN 100
  3. Nexus 5000-A#configure terminal 
    Nexus 5000-B (config) # vsan database 
    Nexus 5000-A (config)# vsan 100 
    Nexus 5000-A (config-vsan) # fcoe vsan 100
  4. Nexus 5000-B# configure terminal 
    Nexus 5000-B(config-vsan) # vlan 100 
    Nexus 5000-B (config-vsan)# vsan 100 name vsan100
Correct answer: A
Explanation:
Reference https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/fcoe/421_n1_1/b_Cisco_n5k_fcoe_config_gd_re_421_n1_1/Cisco_n5k_fcoe_config_gd_re_421_n1_1_chapter4.html
Reference https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/fcoe/421_n1_1/b_Cisco_n5k_fcoe_config_gd_re_421_n1_1/Cisco_n5k_fcoe_config_gd_re_421_n1_1_chapter4.html
Question 7
Which feature allows Cisco Nexus 7000 Series switches to be virtualized at the device level?
  1. PONG
  2. VLAN
  3. VRF
  4. VDC
Correct answer: D
Explanation:
Reference https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-10-slot-switch/White_Paper_Tech_Overview_Virtual_Device_Contexts.html
Reference https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-10-slot-switch/White_Paper_Tech_Overview_Virtual_Device_Contexts.html
Question 8
A Cisco UCS chasis has two power suppliers connected to one PDU and two power supplies connected to another PDU. You would like to protect against the failure of one entire PDU. 
In this scenario, which power policy should you configure in UCS Manager?
  1. N+1
  2. redundant
  3. N+2
  4. grid
Correct answer: D
Explanation:
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/3-0/b_UCSM_GUI_User_Guide_3_0/b_UCSM_GUI_User_Guide_3_0_chapter_0100010.html
Question 9
Your customer needs a new Nexus switch that can support at least ten 40GbE ports, and has room for future growth. Your customer would also like the new switch to be Application Centric Infrastructure- ready. 
Which switch meets these requirements?
  1. Nexus 7004
  2. Nexus 5672
  3. Nexus 6004
  4. Nexus 9504
Correct answer: D
Explanation:
Reference https://www.cisco.com/c/en/us/products/collateral/cloud-systems-management/application-policy-infrastructure-controller-apic/datasheet-c78-732414.html
Reference https://www.cisco.com/c/en/us/products/collateral/cloud-systems-management/application-policy-infrastructure-controller-apic/datasheet-c78-732414.html
Question 10
After deploying a FlexPod solution, which tool would you use to validate a successful installation?
  1. Hardware Universe
  2. Config Advisor
  3. System Manager
  4. UCS Manager
Correct answer: C
Explanation:
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_saphana_n9k_aff.html
Reference https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_saphana_n9k_aff.html
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!