Question 1
An administrator is deploying a FlexPod solution for use with VMware vSphere 6.0. The storage environment consists of a two-node AFF8040 cluster running clustered Data ONTAP 8.3 with a single DS2246 disk shelf fully populated with 800 GB SSD drives. The system is configured to use Advanced Drive Partitioning (ADP). The administrator wants to ensure that each node is configured with the same amount of recourses while also using hot spares for resiliency. 
In this scenario, how many total disk partitions will each node have available for the data aggregate?
  1. 12
  2. 8
  3. 11
  4. 22
Correct answer: B
Question 2
You are asked to configure the computer resources in a FlexPod solution to ensure that jumbo frames are configured end-to-end. 
Which three actions must you perform to accomplish this task? (Choose three.)
  1. Set the MTU size to 1500 on the vNIC template
  2. Enable jumbo frames on all of the switches between the initiator and the iSCI target.
  3. Configure a UCS QoS System Class with the jumbo frames.
  4. Configure jumbo frames on the switch VLANs.
  5. Enable jumbo frames on the operating system adapter.
Correct answer: BCE
Explanation:
Reference https://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-b-series-blade-servers/117601-configure-UCS-00.html
Reference https://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-b-series-blade-servers/117601-configure-UCS-00.html
Question 3
The NetApp Vistual Storage Console is used to set which three setting categories on ESXi hosts? (Choose three.)
  1. MPIO Settings
  2. Adapter Settings
  3. Logging Settings
  4. NFS Settings
  5. Security Settings
Correct answer: ABD
Explanation:
Reference https://library.netapp.com/ecm/ecm_download_file/ECMLP2371569
Reference https://library.netapp.com/ecm/ecm_download_file/ECMLP2371569
Question 4
A server administrator calls you complaining that an uplink on both UCS Fabric Interconnects went down. Each Fabric Interconnect has a vPC to the Nexus 500 switches. After logging in to the switches, you notice that all vPC member ports on the secondary vPC peer switch are down. The vPC peer keepalive is still operational. 
What is the problem in this scenario?
  1. The vPC peer link is down.
  2. Both UCS Fabric Interconnects rebooted.
  3. The vPC feature is disabled.
  4. A new VLAN was added to the UCS vPC member ports.
Correct answer: A
Question 5
An administrator has a FlexPod solution with VMware vSphere. The administrator is migrating all network traffic from standard switches to vSphere distributed switches. Virtual machines (VMs) are currently using VM port groups called VLAN_500 and VLAN_501 on standard virtual switch vSwitch3. A new distributed switch called dvSwitch_VM is created and new distributed port groups are configured for each VM traffic VLAN. VMs are configured to use the new port groups. After the change, VMs on VLAN 501 report a loss of network connectivity; however, VMs on VLAN 500 are not showing any connectivity issues. The symptoms are experienced for VMs on all ESXi hosts. 
Which action must the administrator perform to solve the problem?
  1. Reboot the virtual machines to re-establish network connectivity.
  2. Create a new vmkernel port on dvSwitch_VM for VLAN 501.
  3. Configure the dvSwitch_VM port binding to Ephemeral.
  4. Add the correct VLAN ID to the new distributed port group for VLAN 501.