Question 1
Which scenario would provide the best opportunity to justify the RoCE Express feature?
  1. Shared memory communication from a distributed Linux application to an MQ Linux guest on a z Systems server.
  2. A z/OS WebSphere application that communicates to DB2 running on a z/OS LPAR on a separate z Systems server.
  3. CICS to CICS communication between z/OS LPARs within the same z Systems server.
  4. A Linux system running MQ on a z Systems server communicating to a z/OS MQ within the same server.
Correct answer: A
Explanation:
RoCE Express provides an RDMA capable network adapter providing access to RDMA over Converged Ethernet (RoCE). RoCE provides an optimized network interconnect for System z communications. Along with RoCE Express, z/OS provided a new RDMA based solution called Shared Memory Communications over RDMA (SMC-R). SMC-R is a sockets based solution providing transparent access to RoCE for TCP sockets applications over standard Ethernet.   The IBM System z13 introduces the capability to share (virtualize) the 10GbE RoCE Express feature among multiple (up to 31) LPARs (or z/VM guest virtual machines) using standardized PCIe virtualization (SR-IOV) technology. When RoCE Express is exploited by z/OS with SMC-R, the combined solutions provide two key value points:Improved latency that can provide improved transaction rates for latency sensitive transactional based workloads, and Lower CPU cost for workloads that transfer larger payloads (i.e. analytics, streaming, FTP, big data, data replication, web services, etc.) References: https://www.ibm.com/developerworks/community/blogs/IBMCommserver/entry/ibm_system_z_10gbe_roce_express_virtualization?lang=en
RoCE Express provides an RDMA capable network adapter providing access to RDMA over Converged Ethernet (RoCE). RoCE provides an optimized network interconnect for System z communications. Along with RoCE Express, z/OS provided a new RDMA based solution called Shared Memory Communications over RDMA (SMC-R). SMC-R is a sockets based solution providing transparent access to RoCE for TCP sockets applications over standard Ethernet.   
The IBM System z13 introduces the capability to share (virtualize) the 10GbE RoCE Express feature among multiple (up to 31) LPARs (or z/VM guest virtual machines) using standardized PCIe virtualization (SR-IOV) technology. 
When RoCE Express is exploited by z/OS with SMC-R, the combined solutions provide two key value points:
  • Improved latency that can provide improved transaction rates for latency sensitive transactional based workloads, and 
  • Lower CPU cost for workloads that transfer larger payloads (i.e. analytics, streaming, FTP, big data, data replication, web services, etc.) 
References: https://www.ibm.com/developerworks/community/blogs/IBMCommserver/entry/ibm_system_z_10gbe_roce_express_virtualization?lang=en
Question 2
A customer is considering upgrading a z114 processor currently used as a standalone coupling facility (CF). The customer wants to upgrade to a z13s 2965-N10, but also wants to install additional capacity on this new z13s for two new LPARs running Linux workloads. 
A sizing exercise has determined that the combined CF and Linux workload would total four ICFs, five IFLs, and 600 GB memory. The other systems in the customer’s environment are zEX12 servers. 
The customer is reviewing the design for factors that will influence the hardware configuration. 
Which of the following statements is true for this situation?
  1. Integrated Coupling Adapter (ICA) cards can be installed in the zEC12 servers to improve performance.
  2. The number of available LPARs on z13s may not be sufficient to meet all of the customer’s requirements.
  3. The N10 may not provide sufficient InfiniBand slots for coupling links to the other systems in the customer’s sysplex.
  4. The memory requirement of the configuration will force the N20 model type to be configured.
Correct answer: B
Explanation:
Incorrect Answers:A: The IBM Integrated Coupling Adapter (ICA SR), introduced on the IBM z13 and now available on the IBM z13s.C: Listed below are the minimums and maximums of processor units (PUs) that may be purchased permanently.   D: The IBM 2965 Model N10 supports 64 to 984 GB of memory.References: https://www-01.ibm.com/common/ssi/ShowDoc.wss?docURL=/common/ssi/rep_sm/1/877/ENUS2965-_h01/index.html&lang=en&request_locale=en
Incorrect Answers:
A: The IBM Integrated Coupling Adapter (ICA SR), introduced on the IBM z13 and now available on the IBM z13s.
C: Listed below are the minimums and maximums of processor units (PUs) that may be purchased permanently.
 
D: The IBM 2965 Model N10 supports 64 to 984 GB of memory.
References: https://www-01.ibm.com/common/ssi/ShowDoc.wss?docURL=/common/ssi/rep_sm/1/877/ENUS2965-_h01/index.html&lang=en&request_locale=en
Question 3
A CICS customer wants to modernize their end-user interface for desktops and mobile platforms (notepads, cell phones, etc.) without having to rewrite their programs for each type of device. 
Which software solution can IBM offer to satisfy the requirement?
  1. Mobile containers (Docker) to isolate different mobile devices.
  2. Rational Developer to move the application presentation logic from CICS to Windows.
  3. Mobile OpenStack APIs to connect to applications.
  4. IBM MobileFirst as a single tool with output for multiple end-user devices.
Correct answer: D
Explanation:
The capabilities of running heterogeneous environments on a System z platform and the IBM MobileFirst framework enable an organization to fully support a mobile strategy. The mobile environment, representing the System of Engagement, can integrate with existing back-end core transactional services and data on the System z platform, representing the Systems of Records. The products that are available within the MobileFirst framework can deliver the runtime environment, mobile device management, security, analytics, and development of the application and data platforms in a mobile environment on the System z platform. Figure: End-to-end security checkpoints   MEAP server is protected by a security gateway. The mobile client must authenticate and validate credentials upon encountering the gateway. Note: CICS stands for "Customer Information Control System." It is a general-purpose transaction processing subsystem for the z/OS operating system. CICS provides services for running an application online, by request, at the same time as many other users are submitting requests to run the same applications, using the same files and programs.References: http://www.redbooks.ibm.com/abstracts/tips1162.html?Open
The capabilities of running heterogeneous environments on a System z platform and the IBM MobileFirst framework enable an organization to fully support a mobile strategy. The mobile environment, representing the System of Engagement, can integrate with existing back-end core transactional services and data on the System z platform, representing the Systems of Records. The products that are available within the MobileFirst framework can deliver the runtime environment, mobile device management, security, analytics, and development of the application and data platforms in a mobile environment on the System z platform. 
Figure: End-to-end security checkpoints
 
MEAP server is protected by a security gateway. The mobile client must authenticate and validate credentials upon encountering the gateway. 
Note: CICS stands for "Customer Information Control System." It is a general-purpose transaction processing subsystem for the z/OS operating system. CICS provides services for running an application online, by request, at the same time as many other users are submitting requests to run the same applications, using the same files and programs.
References: http://www.redbooks.ibm.com/abstracts/tips1162.html?Open
Question 4
A customer is planning for the installation of a new LinuxONE Emperor processor. The customer specified Balanced Power Plan Ahead (two line cord pairs). At installation time, they advise that they have only been able to provide power outlets for a single line cord pair. They still want the installation to proceed. 
What action should the technical specialist take to ensure a proper installation?
  1. Advise the customer that the installation cannot proceed until all the configured line cords can be connected.
  2. Request the installation engineer to proceed with the installation with a single line cord pair.
  3. Request the installation engineer to proceed with the installation of one line cord from each pair to the available power outlets.
  4. Create an MES order to remove the Balanced Power Plan Ahead feature until after the installation is complete, then another MES to add the Balanced Power Plan Ahead feature once the extra power outlets are available.
Correct answer: D
Explanation:
References: https://www.ibm.com/support/knowledgecenter/5148-21L/p8haj/hmcinstall.htm
References: https://www.ibm.com/support/knowledgecenter/5148-21L/p8haj/hmcinstall.htm
Question 5
A customer has two z/OS 2964-N63 z13 machines is a single data center and needs the machines to remain up and running without an unscheduled outage. 
Which of the following is considered an element of high availability?
  1. Multiple power cords
  2. Parallel Sysplex
  3. Capacity Planned Event (CPE)
  4. On/Off CoD capability
Correct answer: B
Explanation:
A sysplex is a collection of z/OS systems that cooperate, using certain hardware and software products, to process work. It is a clustering technology that can provide near-continuous availability. A Parallel Sysplex is a sysplex that uses multisystem data-sharing technology A Parallel Sysplex is a cluster of IBM mainframes acting together as a single system image with z/OS. Used for disaster recovery, Parallel Sysplex combines data sharing and parallel computing to allow a cluster of up to 32 systems to share a workload for high performance and high availability. References: https://www.ibm.com/support/knowledgecenter/zosbasics/com.ibm.zos.zmainframe/zconc_clusterPlSys.htm
A sysplex is a collection of z/OS systems that cooperate, using certain hardware and software products, to process work. It is a clustering technology that can provide near-continuous availability. A Parallel Sysplex is a sysplex that uses multisystem data-sharing technology 
A Parallel Sysplex is a cluster of IBM mainframes acting together as a single system image with z/OS. Used for disaster recovery, Parallel Sysplex combines data sharing and parallel computing to allow a cluster of up to 32 systems to share a workload for high performance and high availability. 
References: https://www.ibm.com/support/knowledgecenter/zosbasics/com.ibm.zos.zmainframe/zconc_clusterPlSys.htm
Question 6
What is hybrid cloud?
  1. It is a compute cloud that mixes compute nodes with different CPU architectures.
  2. It is an laaS cloud that provides instances with different operating systems.
  3. It is an architecture that combines public and private clouds.
  4. It is an laaS cloud that provides ephemeral storage only.
Correct answer: C
Explanation:
A hybrid cloud is an integrated cloud service utilizing both private and public clouds to perform distinct functions within the same organization. References: https://www.interoute.com/what-hybrid-cloud
A hybrid cloud is an integrated cloud service utilizing both private and public clouds to perform distinct functions within the same organization. 
References: https://www.interoute.com/what-hybrid-cloud
Question 7
Which of the following is intended to help customers stay current with security and systems integrity fixes and provide Common Vulnerability Scoring System ratings for new APARs?
  1. Resource Link
  2. Fix Central
  3. z Systems Security Portal
  4. IBM Security zSecure Suite
Correct answer: C
Explanation:
The z Systems Security Portal is intended to help you stay current with security and system integrity fixes by providing current patch data and associated Common Vulnerability Scoring System (CVSS) ratings for new APARs. Security Notices are also provided to address highly publicized security concerns. References: https://www-03.ibm.com/systems/z/solutions/security_subintegrity.html
The z Systems Security Portal is intended to help you stay current with security and system integrity fixes by providing current patch data and associated Common Vulnerability Scoring System (CVSS) ratings for new APARs. Security Notices are also provided to address highly publicized security concerns. 
References: https://www-03.ibm.com/systems/z/solutions/security_subintegrity.html
Question 8
A customer running a z13-N63 model 710 realizes they have an upcoming peak that will last for five days. They will need additional processor capacity plus more memory to support this peak. The machine currently has 256GB of pre-planned memory. They have a Customer Initiated Upgrade (CIU) contract already in place. 
Prior to this peak, what should the customer do?
  1. Add five temporary processors using On/Off CoD; although the required temporary memory must be ordered and installed by IBM before the peak.
  2. Use Capacity for Planned Event (CPE) for both the processors and memory needed.
  3. Use CIU to purchase the memory and use On/Off CoD to add temporary processors before the peak.
  4. Use On/Off CoD to add the temporary processors and the temporary memory needed before the peak.
Correct answer: D
Explanation:
Temporary upgrades Three types of upgrades are provided through the following offerings:- On/Off Capacity on Demand (On/Off CoD) - This offering allows you to temporarily add additional capacity or specialty engines due to seasonal activities, period-end requirements, peaks in workload, or application testing. - Capacity Backup (CBU)  This offering allows you to replace model capacity or specialty engines to a backup server in the event of an unforeseen loss of server capacity because of an emergency. - Capacity for Planned Events (CPE)  This offering allows you to replace model capacity or specialty engines due to a relocation of workload during system migrations or a data center move. You can order CPE or CBU temporary upgrade records or related entitlements, such as CBU tests, using the CIU application through Resource Link or calling your IBM sales representative. You can only order an On/Off CoD temporary upgrade using the CIU application through Resource Link. References: IBM Z Capacity on Demand User's Guide (2017), page 2
Temporary upgrades 
Three types of upgrades are provided through the following offerings:
- On/Off Capacity on Demand (On/Off CoD) - 
This offering allows you to temporarily add additional capacity or specialty engines due to seasonal activities, period-end requirements, peaks in workload, or application testing. 
- Capacity Backup (CBU)  
This offering allows you to replace model capacity or specialty engines to a backup server in the event of an unforeseen loss of server capacity because of an emergency. 
- Capacity for Planned Events (CPE)  
This offering allows you to replace model capacity or specialty engines due to a relocation of workload during system migrations or a data center move. 
You can order CPE or CBU temporary upgrade records or related entitlements, such as CBU tests, using the CIU application through Resource Link or calling your IBM sales representative. You can only order an On/Off CoD temporary upgrade using the CIU application through Resource Link. 
References: IBM Z Capacity on Demand User's Guide (2017), page 2
Question 9
A customer has an IBM z13 and is using z/OS for XML file handling. The customer needs a solution which allows compression of large XML files in DEFLATE file format for cross platform data exchange with third parties. 
What should be recommended to use as a proof of concept?
  1. 10GbE RoCE Express
  2. Compression Coprocessor on IBM z Systems processor chip
  3. Flash Express
  4. zEDC Express
Correct answer: D
Explanation:
zEDC is a compression acceleration capability, that enables you to do hardware-based data compression and decompression. It is designed for high-performance, low-latency compression, to reduce processor use, optimize the performance of compression-related tasks, improve disk usage, and optimize cross-platform exchange of data. The compression format generated and used by zEDC Express is the Request for Comments (RFC) 1951 DEFLATE format, an industry standard that compresses data using the Lempel-Ziv 1977 (LZ77) and Huffman coding algorithms. Incorrect Answers:A: In 2013 the IBM zEC12 (zBC12) introduced the 10GbE RoCE Express feature. RoCE Express provides an RDMA capable network adapter providing access to RDMA over Converged Ethernet (RoCE). RoCE provides an optimized network interconnect for System z communications.References: Reduce Storage Occupancy and Increase Operations Efficiency with IBM zEnterprise Data Compression (February 2015), page 2
zEDC is a compression acceleration capability, that enables you to do hardware-based data compression and decompression. It is designed for high-performance, low-latency compression, to reduce processor use, optimize the performance of compression-related tasks, improve disk usage, and optimize cross-platform exchange of data. 
The compression format generated and used by zEDC Express is the Request for Comments (RFC) 1951 DEFLATE format, an industry standard that compresses data using the Lempel-Ziv 1977 (LZ77) and Huffman coding algorithms. 
Incorrect Answers:
A: In 2013 the IBM zEC12 (zBC12) introduced the 10GbE RoCE Express feature. RoCE Express provides an RDMA capable network adapter providing access to RDMA over Converged Ethernet (RoCE). RoCE provides an optimized network interconnect for System z communications.
References: Reduce Storage Occupancy and Increase Operations Efficiency with IBM zEnterprise Data Compression (February 2015), page 2
Question 10
A customer has a z13 server. They plan to use Server Time Protocol (STP) for accessing an external time source (UTC). 
Which of the following techniques can be used to get the time information in this scenario?
  1. Configuration of a Network Time Protocol (NTP) client on the HMC which accesses an external NTO server.
  2. Use of an External Time Reference (9037-002) in an STP mixed Coordinated Timing Network.
  3. SE dial out to an external time reference.
  4. Edit PR/SM to connect oscillator cards to a tlsdate server.
Correct answer: B
Explanation:
Network Time Protocol (NTP) client support The external time source (ETS) function of STP can provide accurate time relative to an external time standard for data processing applications. The ETS function is only available when an STP-only CTN is configured. The external time source can be configured by dialing out from the HMC to an available time service such as Automated Computer Time Service (ACTS). Dialing out provides time accuracy for the z Systems timing network only. This function has been generally available since January 31, 2007 when STP became generally available. An alternative method to obtain accurate time is from an NTP server. Simple Network Time Protocol (SNTP) client support is added to the Server Time Protocol code to interface with NTP servers. NTP client support can provide the same time across heterogeneous platforms in an enterprise with a time accuracy of 100 milliseconds. References: https://www-03.ibm.com/systems/z/advantages/pso/stp/ntp.html
Network Time Protocol (NTP) client support 
The external time source (ETS) function of STP can provide accurate time relative to an external time standard for data processing applications. The ETS function is only available when an STP-only CTN is configured. The external time source can be configured by dialing out from the HMC to an available time service such as Automated Computer Time Service (ACTS). Dialing out provides time accuracy for the z Systems timing network only. This function has been generally available since January 31, 2007 when STP became generally available. 
An alternative method to obtain accurate time is from an NTP server. Simple Network Time Protocol (SNTP) client support is added to the Server Time Protocol code to interface with NTP servers. NTP client support can provide the same time across heterogeneous platforms in an enterprise with a time accuracy of 100 milliseconds. 
References: https://www-03.ibm.com/systems/z/advantages/pso/stp/ntp.html