Download Designing HPE Nimble Solutions.HPE2-K42.PassLeader.2019-03-09.62q.vcex

Vendor: HP
Exam Code: HPE2-K42
Exam Name: Designing HPE Nimble Solutions
Date: Mar 09, 2019
File Size: 696 KB

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Demo Questions

Question 1
Which prerequisites must be fulfilled before starting the array initialization? (Choose three)
  1. HPE Nimble Windows Toolkit installed on a server/laptop.
  2. Ensure your laptop/server IP has a static IP address configured on the same subnet as the array management interface.
  3. Array updated to the latest firmware.
  4. All switch configurations done like flow control and spanning tree.
  5. Array registered in InfoSight based on the serial number.
  6. HPE Service Processor deployed
Correct answer: ABC
Question 2
How is SmartReplicate licensed?
  1. per array
  2. free of charge
  3. per target
  4. based on capacity (per 1TB)
Correct answer: B
Explanation:
Reference: https://community.hpe.com/t5/Array-Performance-and-Data/Nimble-SmartSnap-SmartReplication-vs-EMC-RecoveryPoint/td-p/6983058#.XBCRDsRR2kw
Reference: https://community.hpe.com/t5/Array-Performance-and-Data/Nimble-SmartSnap-SmartReplication-vs-EMC-RecoveryPoint/td-p/6983058#.XBCRDsRR2kw
Question 3
What is the maximum number of banks in an AF-Series array?
  1. 1
  2. 2
  3. 3
  4. 4
Correct answer: B
Question 4
What is a valid QoS performance setting?
  1. latency threshold
  2. IOPS minimum
  3. IOPS limit
  4. MB/s minimum
Correct answer: C
Explanation:
QoS-Limit allows a user to limit either the IOP or MB/s performance of a specific workload.  Having the ability to limit both IOPS and MBs is important as quite often any single workload will have different peaks and troughs during the operational day.  For instance, an OLTP workload maybe very latency sensitive to small block updates during the working day when rows and tables are frequently being accessed or updated (this will tend to be very IOP/latency sensitive) yet in the evening the same database maybe receiving feeds from other systems (or providing bulk updates/analysis or index rebuilds), the same application will cease to be IOP sensitive and will now be bandwidth (MBs) sensitive.  In NimbleOS4 a user can limit a workload by either IOPS or MBs and also specify limits to both IOPS and MBs.  If either limit is reached then the volume will be restricted accordingly. Reference: https://community.hpe.com/t5/HPE-Storage-Tech-Insiders/NimbleOS-4-Quality-of-Service-QoS-Limits/ba-p/6986455#.XBEAvMRR2kw
QoS-Limit allows a user to limit either the IOP or MB/s performance of a specific workload.  Having the ability to limit both IOPS and MBs is important as quite often any single workload will have different peaks and troughs during the operational day.  For instance, an OLTP workload maybe very latency sensitive to small block updates during the working day when rows and tables are frequently being accessed or updated (this will tend to be very IOP/latency sensitive) yet in the evening the same database maybe receiving feeds from other systems (or providing bulk updates/analysis or index rebuilds), the same application will cease to be IOP sensitive and will now be bandwidth (MBs) sensitive.  In NimbleOS4 a user can limit a workload by either IOPS or MBs and also specify limits to both IOPS and MBs.  If either limit is reached then the volume will be restricted accordingly. 
Reference: https://community.hpe.com/t5/HPE-Storage-Tech-Insiders/NimbleOS-4-Quality-of-Service-QoS-Limits/ba-p/6986455#.XBEAvMRR2kw
Question 5
What are primary HPE Nimble SmartReplicate components? (Choose three.)
  1. partner
  2. snapshot schedule
  3. replication group
  4. sync partner
  5. throttle
Correct answer: ABE
Question 6
How should the All-Flash shelf be connected to the controller shelf?
  1. Cable the All-Flash shelf directly to the last disk shelf.
  2. Cable the All-Flash shelf directly to the controller shelf.
  3. Use high performance SAS expanders.
  4. Cable the All-Flash shelf directly to the first disk shelf.
Correct answer: B
Question 7
What is the correct power on/off order of the All Flash-Series? (Choose two.)
  1. power off the controller shelf first, then the expansion shelves
  2. power on controller shelf first, then the expansion shelves
  3. power on expansion shelves first, then the controller shelf
  4. power off the expansion shelves first, then the controller shelf
Correct answer: AC
Explanation:
Reference: https://www.reddit.com/r/storage/comments/3ii6dt/nimble_array_remote_shutdown_during_power_outage/
Reference: https://www.reddit.com/r/storage/comments/3ii6dt/nimble_array_remote_shutdown_during_power_outage/
Question 8
How can controller failover be performed? (Choose two.)
  1. In CLI, use the command: failover.Perform it online via InfoSight.
  2. In WebUI, on the array level, click MAKE ACTIVE.
  3. In OCP, press the Failover button.
  4. Perform it online via InfoSight.
Correct answer: AB
Question 9
Which kind of licensing approach do HPE Nimble arrays use?
  1. capacity-based licensing
  2. controller-based licensing
  3. all-inclusive licensing
  4. frame-based licensing
Correct answer: C
Question 10
List basic replication steps in the correct order. 
Correct answer: To work with this question, an Exam Simulator is required.
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!