Download HPE Compute Solutions.HPE0-S60.VCEplus.2022-11-16.19q.vcex

Vendor: HP
Exam Code: HPE0-S60
Exam Name: HPE Compute Solutions
Date: Nov 16, 2022
File Size: 413 KB
Downloads: 1

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Demo Questions

Question 1
You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group What should you check to fix the issue?
  1. if both FiexNICs are configured with the same speed
  2. If the logical enclosure is built on at least three HPE Synergy frames
  3. if both FiexNICs are connected to different networks
  4. if the logical enclosure is configured with redundant master modules
Correct answer: A
Explanation:
Question 2
Your customer experienced some problems caused by outdated HPE Superdome Flex firmware.
Which update method should they use to avoid these issues in the future?
  1. HPE OneView method for I/O firmware update procedure
  2. RMC CLI to update I/O and HPE Persistent Memory firmware
  3. HPE OneView IT HPE Persistent Memory firmware must be updated.
  4. HPE SUM if HPE Persistent Memory firmware must be updated
Correct answer: B
Explanation:
Question 3
Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen 10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?
  1. Migrate the application to a Logical JBOD and connect it to the new server
  2. Copy the server profile and assign the clone to the new hardware
  3. Edit the server profile and change server hardware type
  4. Create a new server profile template and apply to the new hardware
Correct answer: C
Explanation:
Question 4
Your customer has me following HPE Synergy setup
  • Three frames fully populated with HPE Synergy 480 Gen10 Plus modules and 25Gb/s downlink speed formulating a single logical enclosure
  • Two HPE Virtual Connect SE 100Gb F32 Module for Synergy
  • Four HPE Synergy 50Gb interconnect Link Module
  • Six HPE Synergy Virtual Connect SE 32Gb FC Modules
The customer needs to add a frame.
Which statement about the expansion of this setup is true?
  1. The additional frame must have HPE Virtual Connect FC modules installed
  2. The customer can grow the existing logical enclosure up to 5 frames
  3. The customer has to create a new logical enclosure for the additional frame
  4. The additional frame cannot have 12Gb SAS connection modules installed
Correct answer: C
Explanation:
Question 5
Your customer plans to deploy HPE OneView for VMware vCenter Server together with HPE Storage Integration Pack for VMware vCenter. The customer wants to use them to manage HPE Synergy Gen10 compute modules. HPE ProLiant Gen 10 servers and an MSA array.
Which statement about compatibility of the existing environment with the planned software components is true?
  1. Both HPE Synergy Gen10 full-height compute module plugins will require a license
  2. HPE OneView for VMware vCenter Server does not support standalone HPE ProLiant servers
  3. To use the required plugins HPE ProLiant Gen10 systems must be managed using HPE OneView
  4. HPE Storage integration Pack for VMware vCenter does not support MSA arrays
Correct answer: B
Explanation:
Question 6
Refer to the exhibit.
   
Which statement about this logical interconnect group is true?
  1. Both modules are located in different frames for redundancy
  2. For an uplink set, ports from different modules can be selected
  3. interconnect modules are installed in interconnect bays 1 and 4
  4. An additional license is required to change the enclosure count
Correct answer: D
Explanation:
Question 7
Your customer plans to add four HPE Synergy frames to an existing management ring Ail installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.
Which statement about mixing different FLM modules is true?
  1. Existing 2-port FLM modules must be replaced with 4-port FLM modules
  2. A management ring can contain mixed frame link module configurations
  3. A management ring with mixed FLM modules cannot have more than 12 frames
  4. Mixing different FLM modules is allowed if all of them have the same firmware version
Correct answer: C
Explanation:
Question 8
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?
  1. Virtual Distributed Switchwww.VCEplus.io
  2. vSphere Standard license
  3. Load balancing cluster
  4. Dedicated VMKernel port
Correct answer: D
Explanation:
Question 9
Which statement about HPE OneView milestone releases is true?
  1. A milestone release is a release which must be installed on HPE Composer to support current version of the Service Pack for Synergy
  2. A milestone release is a release that is published when HPE releases new hardware components to immediately support new systems
  3. A milestone release is available for selected partners that give access to HPE OneView features which are not officially announced.
  4. A milestone release is a release with an enhanced update architecture mat is a prerequisite prior to updating to a subsequent release.
Correct answer: A
Explanation:
Question 10
Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller Installed and two 12Gb SAS switches installed in the first fabric.
The customer reports that compute nodes cannot access the storage module. What should you verify first when troubleshooting this problem?
  1. If the D3940 module is imported in managed state that allows volume provisioning.
  2. If there Is a logical interconnect created based on the 12Gb SAS switches.
  3. If the D3940 storage module is property licensed through HPE OneView interface.
  4. If there is at least one ISCSI network configured that will provide access to the module.
Correct answer: A
Explanation:
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!