Download Dell XtremIO Maintenance Achievement.D-XTR-MN-A-24.VCEplus.2024-08-14.38q.vcex

Vendor: Dell
Exam Code: D-XTR-MN-A-24
Exam Name: Dell XtremIO Maintenance Achievement
Date: Aug 14, 2024
File Size: 684 KB

How to open VCEX files?

Files with VCEX extension can be opened by ProfExam Simulator.

Demo Questions

Question 1
What is a feature of the XtremlO storage array?
  1. Inline compression
  2. Post process deduplication
  3. Synchronous replication
  4. Disk sparing
Correct answer: A
Explanation:
A key feature of the XtremIO storage array is inline compression. This feature allows data to be compressed in real-time as it is written to the storage system, which helps to reduce storage footprint and improve storage efficiency without impacting performance.
A key feature of the XtremIO storage array is inline compression. This feature allows data to be compressed in real-time as it is written to the storage system, which helps to reduce storage footprint and improve storage efficiency without impacting performance.
Question 2
Which document contains the detailed steps for re-imaging the Storage Controller when preparing for a single-to-dual X-Brick expansion?
  1. XtremlO Site Preparation Guide
  2. XtremlO Installation Summary Form
  3. XtremIO Hardware Installation and Upgrade Guide
  4. XtremlO Software Installation and Upgrade Guide
Correct answer: C
Explanation:
Questions no: Which document contains the detailed steps for re-imaging the Storage Controller when preparing for a single-to-dual X-Brick expansion?Verified Answer: C. XtremIO Hardware Installation and Upgrade GuideStep by Step Comprehensive Detailed Explanation with References: The detailed steps for re-imaging the Storage Controller when preparing for a single-to-dual X-Brick expansion are contained in the XtremIO Hardware Installation and Upgrade Guide. This document provides comprehensive instructions on the physical installation, initial configuration, and upgrade procedures for XtremIO hardware components, including the process of reimaging the Storage Controller1.The steps typically include:Ensuring that all data is backed up before starting the re-imaging process.Verifying the current system configuration and health status.Following the specific instructions for re-imaging the Storage Controller as outlined in the guide.Performing post-re-imaging tasks such as system verification and configuration as necessary.It is important to follow the guide closely to avoid any potential issues during the expansion process1.
Questions no: Which document contains the detailed steps for re-imaging the Storage Controller when preparing for a single-to-dual X-Brick expansion?
Verified Answer: C. XtremIO Hardware Installation and Upgrade Guide
Step by Step Comprehensive Detailed Explanation with References: The detailed steps for re-imaging the Storage Controller when preparing for a single-to-dual X-Brick expansion are contained in the XtremIO Hardware Installation and Upgrade Guide. This document provides comprehensive instructions on the physical installation, initial configuration, and upgrade procedures for XtremIO hardware components, including the process of reimaging the Storage Controller1.
The steps typically include:
Ensuring that all data is backed up before starting the re-imaging process.
Verifying the current system configuration and health status.
Following the specific instructions for re-imaging the Storage Controller as outlined in the guide.
Performing post-re-imaging tasks such as system verification and configuration as necessary.
It is important to follow the guide closely to avoid any potential issues during the expansion process1.
Question 3
Which type of InfiniBand switch is used in a multi-brick XtremIO X2-R array?
  1. 36 port switch
  2. 18 port switch
  3. 24 port switch
  4. 12 port switch
Correct answer: A
Explanation:
In a multi-brick XtremIO X2-R array, a 36 port InfiniBand switch is used. This type of switch provides the necessary number of ports to accommodate the connectivity requirements of a multi-brick configuration, ensuring highspeed data transfer and communication between the bricks and other components of the storage array1.The InfiniBand switch plays a crucial role in the XtremIO X2-R's architecture, as it allows for the interconnection of multiple bricks, which collectively contribute to the array's performance and scalability. The 36 port switch ensures that there are enough ports available for current use and potential future expansion1.
In a multi-brick XtremIO X2-R array, a 36 port InfiniBand switch is used. This type of switch provides the necessary number of ports to accommodate the connectivity requirements of a multi-brick configuration, ensuring highspeed data transfer and communication between the bricks and other components of the storage array1.
The InfiniBand switch plays a crucial role in the XtremIO X2-R's architecture, as it allows for the interconnection of multiple bricks, which collectively contribute to the array's performance and scalability. The 36 port switch ensures that there are enough ports available for current use and potential future expansion1.
Question 4
Why is an extra rack unit space used between X-Bricks when installing a multi X-Brick XtremIO X2?
  1. Manage the air flow between Storage Controllers
  2. Accommodate the cable management duct
  3. Provide space for an additional XMS
  4. Accommodate the routing for InfiniBand cables
Correct answer: B
Explanation:
An extra rack unit space is used between X-Bricks when installing a multi X-Brick XtremIO X2 to accommodate the cable management duct. This space is essential for organizing and managing the cables, ensuring proper airflow, and making maintenance tasks easier.
An extra rack unit space is used between X-Bricks when installing a multi X-Brick XtremIO X2 to accommodate the cable management duct. This space is essential for organizing and managing the cables, ensuring proper airflow, and making maintenance tasks easier.
Question 5
From bottom to top, what is the correct racking order of the first four components to expand an XtremlO X1 configuration from a dual X-Brick to a quad X-Brick?
Correct answer: To work with this question, an Exam Simulator is required.
Question 6
In an XtremIO X2, what is the maximum number of lifetime cycles for NVRAM?
  1. 7,000
  2. 5,000
  3. 4,000
  4. 10,000
Correct answer: D
Explanation:
In an XtremIO X2 system, the maximum number of lifetime cycles for NVRAM is 10,000. This number represents the total count of write and erase cycles the NVRAM can endure throughout its lifespan, ensuring data integrity and reliability over time.
In an XtremIO X2 system, the maximum number of lifetime cycles for NVRAM is 10,000. This number represents the total count of write and erase cycles the NVRAM can endure throughout its lifespan, ensuring data integrity and reliability over time.
Question 7
Into which directory must the XtremApp software be copied on the XMS?
  1. /xtremapp
  2. /media
  3. /home
  4. /images
Correct answer: A
Explanation:
The XtremApp software must be copied into the /xtremapp directory on the XtremIO Management Server (XMS). This directory is specifically designated for the XtremApp software, ensuring that it is stored in the correct location for installation and execution1.The process for copying the software typically involves:Accessing the XMS via a secure shell (SSH) connection.Navigating to the root directory.Locating or creating the /xtremapp directory.Using the appropriate command to copy the XtremApp software from its source location to the /xtremapp directory on the XMS.It is important to follow the Official Dell XtremIO Maintenance Achievement document for the correct procedures and to ensure that the software is placed in the proper directory for successful installation and operation1.
The XtremApp software must be copied into the /xtremapp directory on the XtremIO Management Server (XMS). This directory is specifically designated for the XtremApp software, ensuring that it is stored in the correct location for installation and execution1.
The process for copying the software typically involves:
Accessing the XMS via a secure shell (SSH) connection.
Navigating to the root directory.
Locating or creating the /xtremapp directory.
Using the appropriate command to copy the XtremApp software from its source location to the /xtremapp directory on the XMS.
It is important to follow the Official Dell XtremIO Maintenance Achievement document for the correct procedures and to ensure that the software is placed in the proper directory for successful installation and operation1.
Question 8
Where can the XtremlO power requirements be found?
  1. XtremIO Storage Array Software Installation and Upgrade Guide
  2. XtremIO Storage Array Hardware Installation and Upgrade Guide
  3. XtremIO Storage Array Site Preparation Guide
  4. XtremIO Storage Array Pre-Installation Checklist
Correct answer: C
Explanation:
The XtremIO Storage Array Site Preparation Guide contains the power requirements for the XtremIO system. This guide includes detailed specifications for power consumption, electrical requirements, and other environmental factors necessary for proper installation and operation.
The XtremIO Storage Array Site Preparation Guide contains the power requirements for the XtremIO system. This guide includes detailed specifications for power consumption, electrical requirements, and other environmental factors necessary for proper installation and operation.
Question 9
Which document should be referenced when modifying the IP addresses on an XtremIO X2 cluster that will remain in the same IP network?
  1. XtremIO Software Installation and Upgrade Guide
  2. RESTful API Guide
  3. XtremIO Site Planning Guide
  4. XtremIO Storage Array User Guide
Correct answer: D
Explanation:
When modifying the IP addresses on an XtremIO X2 cluster that will remain in the same IP network, the appropriate document to reference is the 'XtremIO Storage Array User Guide.' This guide contains detailed instructions and best practices for changing network configurations, including IP address modifications.
When modifying the IP addresses on an XtremIO X2 cluster that will remain in the same IP network, the appropriate document to reference is the 'XtremIO Storage Array User Guide.' This guide contains detailed instructions and best practices for changing network configurations, including IP address modifications.
Question 10
When comparing XtremlO X1 to XtremlO X2, how much memory is installed in a Storage Controller that has a DAE attached with 400 GB SSDs?
  1. X1: 256 GB; X2: 384 GB
  2. X1: 256 GB; X2: 512 GB
  3. X1: 384 GB; X2: 384 GB
  4. X1: 512 GB; X2: 1024 GB
Correct answer: B
Explanation:
When comparing XtremIO X1 to XtremIO X2, the amount of memory installed in a Storage Controller with a DAE attached with 400 GB SSDs differs. For the X1, it is 256 GB, while for the X2, it is 512 GB. This increase in memory in the X2 model supports higher performance and improved handling of data operations.
When comparing XtremIO X1 to XtremIO X2, the amount of memory installed in a Storage Controller with a DAE attached with 400 GB SSDs differs. For the X1, it is 256 GB, while for the X2, it is 512 GB. This increase in memory in the X2 model supports higher performance and improved handling of data operations.
HOW TO OPEN VCE FILES

Use VCE Exam Simulator to open VCE files
Avanaset

HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files
ProfExam Screen

ProfExam
ProfExam at a 20% markdown

You have the opportunity to purchase ProfExam at a 20% reduced price

Get Now!